Product Name | |
Gear Type | Product Type |
K6BH20NU | K6BH20NU |
K6BH20NC | K6BH20NC |
K8BH40NU | K8BH40NU |
K8BH40NC | K8BH40NC |
K9BH90NU | K9BH90NU |
K9BH90NC | K9BH90NC |
K9BH150NC | K9BH150NC |
K9BH200NC | K9BH200NC |
Rating Output (Cont) |
Power Input |
Frequency |
W | Voltage (Single Phase) |
Hz |
20 | 100~115 | 50/60 |
40 | 200~230 | |
100~115 | ||
90 | 200~230 | |
110~115 | ||
150 | 200~230 | |
200~230 | ||
200 | 200~230 |
Rating Input Current |
Maximum Input Current |
Rating Torque |
A | A | N·m (kgf·cm) |
0.95 | 1.55 | 0.1 (1.0) |
0.55 | 0.9 | 0.2 (2.0) |
1.45 | 2.5 | |
0.85 | 1.4 | 0.45 (4.5) |
2.55 | 3.9 | |
1.45 | 2.4 | 0.49 (4.9) |
2.1 | 4 | |
2.5 | 4 | 0.65 (6.5) |
Starting Torque |
Rating Rotation Speed |
Speed Control Range |
N·m (kgf·cm) | r/min | r/min |
0.12 (1.2) | 2000 | 100~2000 |
0.24 (2.4) | ||
0.54 (5.4) | 3000 | 100~3000 |
0.63 (6.3) | ||
0.81 (8.1) |
Motor Allowed Load Inertia Moment |
Speed Change Rate |
|||
J kg·m² | GD² kgf·cm² | Load | Voltage | Temperature |
0.5×10-4 | 2 | Less than or equal to ±1% (0~Rating torque, If rotating at the rated speed) |
Less than or equal to ±1% (Power voltage ±10%, If rotating at the rated speed No Load) |
Less than or equal to ±1% (0~+40℃, If rotating at the rated speed No Load) |
1.8×10-4 | 7.2 | |||
5.8×10-4 | 23.2 | |||
5.8×10-4 | 23.2 | |||
6.0×10-4 | 24 |
Items | Specifications |
Rotating Speed Setting Method |
Controller panel’s speed |
Acceleration Time Decelaration Time |
0.5~10 seconds : 2000 r/min no load (It may change depending on the load size) To set acceleration time, it’s set at slow start on the front panel To set deceleration time, it’s set at slow stop |
Input Signal | Photo coupler input method, operating at input resistance of 10㏀ DC 12V±10%, Common in EXT, CW, and CCW |
Output Signal | Open collector output, External use conditions : less than 26.4V 10㎃, common in SPEED OUT/ ALARM OUT |
Protection Function | If the following protection function is operating, then control unit alarm signal gets generated and motor stops automatically.Overload protection function : If more than the rated torque is applied to the motor for more than 5 seconds Overvoltage protection function : If voltage applied to the control unit goes over the upper bound of the rating voltage allowance Open phase protection : If cable sensor line gets disconnected during motor operation Undervoltage protection : If voltage applied to the control unit is less than the lower bound of the rating voltage allowance Over speed protection : If motor rotation speed is faster than 2500 r/min |
Motor Insulation Class | E Type (120℃) |
Maximum Extension Distance | The distance between motor – control unit is 10.5m (optional KBEW-10 extension cable is used) |
Rated Time | Continuous |